• Turn-Key Hot Tap Projects

    Author: Mock Webware |

    In-House Engineering and design package submissions to meet all ASME Provincial Regulatory bodies (with exception of Quebec)

    CLICK HERE TO READ THE FULL ARTICLE »


  • Hot Tap Capabilities

    Author: Mock Webware |

    Branch Reducing Hot Taps Olet (Weldolet, Sockolet, Threadolet) Split Tee (Size on Size Application) Tank Nozzle & Repad Outlets Extended Reach/ Below Grade Riser Applications Riser Applications up 6.1m or 20’ Depth for branch connections 2” to 8” Diameter Branch Diameters 10” and Greater up to 3.5m or 10’ Red Flame Pro (Pig) Bar System if required Valve Drill Out Thermowell, Pig Signal, or Injection Nozzles Capabilities Hot Tap Branches 0.25” to 48” Outlet Pressures Up To 5,000 PSI (35,000 kPa) Design Temperatures up to 371 °C (700 °F)   Branch and Tap Types Branch Reducing Hot Taps Olet (Weldolet, Sockolet, Threadolet) Split Tee (Size on Size Application) Tank Nozzle & Repad Outlets Extended Reach/ Below Grade Riser Applications Riser Applications…

    CLICK HERE TO READ THE FULL ARTICLE »


  • Cold Tap Project

    Author: Mock Webware |

    Red Flame Fastening Tee (Mechanical Cold Tap Connection For Pressure Confirmation and De-Pressuring. Applicable to Pipeline, Drilling Pipe, Well Head/ Well Piping, Coil Tubing and more! New Construction or Outage Branch Installations ( Perform Branch Taps without purging stagnant or line contained fluid or gas. Full Scope Well Head Re-Entry and Well Abandonment Cut and Cap Full Pipeline Cut and Caps Mechanical or Self Sealing Branch Connections Red Flame Fastening Tee (RFT) ◦ Mechanical Cold Tap Connection For Pressure Confirmation and De-Pressurizing. ◦ Applicable to Pipeline, Drilling Pipe, Well Head/ Well Piping, Coil Tubing and more! New Construction or Outage Branch Installations ◦ Perform Branch Taps without purging stagnant or…

    CLICK HERE TO READ THE FULL ARTICLE »


  • Line Stopping

    Author: Mock Webware |

    Low Pressure Single and Double-Block-and-Bleed Isolation Bag System (Up to 100PSI/ 690KPA Operating) Low Pressure Sealing Cup Applications (Up to 100PSI/ 690KPA Operating) High Pressure Single and Double-Block-and-Bleed Pivot Head Line Isolation System With or Without Line By-Pass Requirements High Pressure Single Port Double-Block-and-Bleed System With or without Line By-Pass Requirement Red Flame No-Leak Completion Pro-Plug System for Valve Removal Capabilities High Pressure Systems - Size: 2” up to 24” (Pressure: 750 PSI / 5171 kPa) Low Pressure Systems - Size: 3” up to 72” (Pressure: 100 PSI / 690 kPa Temperatures - 0 °C to 242 °C (32 °F to 462 °F)   Line Stop Types Low Pressure Kevlar Isolation Bag System…

    CLICK HERE TO READ THE FULL ARTICLE »


Top
Top